Power Factor Correction
Power quality is critical to efficient operation of equipment. One contributing element to power quality is power factor.
Static Var Compensators (SVCs) are systems, or a set of devices, that create voltage stability in high voltage electrical systems. Through the use of state-of-the-art high voltage thyristor valves and thyristor-controlled reactors, Merus SVC generate fast response reactive power.
Fast reactive power compensation with Merus SVC ensures effective flicker mitigation and voltage variation control in steel plants with electric arc furnaces (EAFs), in mining plants with mine winders, excavators, crushers and grinders or to enhance transmission capacity and achieve unity power factor in utilities. Merus SVC provides tailored solutions to meet customer requirements from 3.3KV up to 38.5kV 250MVAr. Merus Power can deliver a complete turnkey solutions.
Merus Static Var Compensator is an effective power quality solution for steel, metal, mining and electrical utilities.
Each SVC system is tailor-made to fit the network fault level and load parameters.
The Merus Static Var Compensator’s state-of-the-art high voltage thyristor valve, reliable controller, modern user interface and redundant technical design are combined into a fast, reliable and robust system that is easy to operate and complies with all standard communication protocols.
The Static Var Compensator is connected parallel with the load to be compensated. The system provides reactive power in proportion to the system supply voltage.
Thyristor-controlled reactors (TCR) generate SVC’s inductive power and passive filter capacitor banks generate its capacitive power. As TCR also generates harmonic currents, the capacitor banks are fine tuned for not only reducing harmonics generated by the load but also from the system itself.
The thyristors are net commutated thus they can be turned on once per cycle. This feature along with the control and measuring strategy define response time for reactive power and voltage changes. When open loop control strategy is implemented, the typical response time of the SVC system is 10ms (50Hz).
Merus control & protection system guarantees superior performance for flicker mitigation, reactive power control, power factor control and voltage stabilisation. Advanced protection system ensures that the components are well protected against unexpected system fault conditions. Master controller regulates the operation of thyristor valve in order to respond to the system’s reactive power requirements.
The system can be built for all medium voltage levels starting from 3.3kV all the way up to 38.5kV. The power output range starts from 4Mvar up to 250Mvar and the systems can be connected parallel for a higher total output.
In the heart of the system is Merus thyristor valve that is developed to meet the demands of performance and reliability in harsh industrial environment. Due to its mechanical composite construction, the size of the valve is compact and it can be installed even in a standard sea freight container. The electronics are simple and robust, but the device is still equipped with comprehensive monitoring and electrical protection features. All communication between high voltage thyristor disc level and ground control system is utilizing fibre optics which makes long distance signal transfer possible.
Typical Captech SVC project activities include:
Merus STATCOM and Merus SVC both are proven and reliable solutions to solve power quality challenges. To select the right solution for your specific power quality challenge and application, please feel free to contact us. Our experts will be happy to analyse your power quality challenge and suggest the right solution.
13/40 Edina Road Ferntree Gully VIC 3156 © copyright 2021 19 106 461 385 Site by Sticky Terms & Conditions